Sense Data<br />

085A Specific Server Exception. An architecturally defined or customer-defined<br />

server that is sensitive to data object contents has detected an exception.<br />

085B Unknown Resource Name. The identified resource, required to complete the<br />

requested unit-of-work, is not known to the SNA node.<br />

085C System Exception. The node experiences an exception condition within a<br />

resident system or subsystem that inhibits subsequent processing by the SNA<br />

component.<br />

085D The MU ID could not be accepted in the MU_ID registry.<br />

085E Operator Intervention.<br />

085F Reserved.<br />

0860 Function Not <strong>Support</strong>ed–Continue Session. The function requested is not<br />

supported; the function may have been specified by a request code or some<br />

other field, control character, or graphic character in an RU.<br />

0861 Invalid COS Name. The class of service (COS) name, either specified by the<br />

ILU or generated by the SSCP of the SLU from the mode table is not in the<br />

“COS name to VR identifier list” table used by the SSCP of the PLU.<br />

0862 Medium Presentation Space Recovery. An error has occurred on the current<br />

presentation space. Recovery consists of restarting at the top of the current<br />

presentation space. The sequence number returned is of the RU in effect at the<br />

top of the current presentation space.<br />

0863 Referenced Local Character Set Identifier (LCID) Not Found. A referenced<br />

character set does not exist.<br />

0864 Function Abort. The conservation was terminated abnormally. Other<br />

terminations may occur after repeated reexecutions; the request sender is<br />

responsible to detect such a loop.<br />

0865 Retired.<br />

0866 Retired.<br />

0867 Sync Event Response. Indicates a [00ff]20 required negative response to an<br />

(RQE,CD) synchronizing request.<br />

0868 No Panels Loaded. Referenced format not found because no panels are loaded<br />

for the display.<br />

0869 Panel Not Loaded. The referenced panel is not loaded for the display.<br />

086A Subfield Key Invalid. A subfield key in an MS subvector was not valid in the<br />

conditions under which it was processed.<br />