Event 4 EVENT/ERROR DETECTED AT L4 (TRANSPORT)<br />

DCE FEATURE–STATE/PROTOCOL VIOLATION<br />

DTP<br />

Description: The DCE feature module (PDNNET) received an invalid primitive from<br />

layer 3 across the Layer 3/4 Platform, or from its peer because of the state that<br />

PDNNET perceives the connection. The MCT containing the PCALL packet received<br />

from layer 3, or the first part of the message buffer received from its peer is included<br />

in this event.<br />

R13: Virtual address in PDNNET module in which error occurred<br />

Attributes affected: Supplementary text message, Error event. The X.25 PSCS<br />

program product generates this CENLOG. Procedure: PDNETP.<br />

Description: DTP has detected an error in a recognizable service primitive control<br />

message. <strong>Telcon</strong> generates this CENLOG.<br />

INSTDC<br />

Description: INSTDC received error status from EUSERV when it tried to open a<br />

session with a remote central logging <strong>Telcon</strong> node. May be caused by improper<br />

configuration of XEU that defines remote logging point. R1 contains the error code<br />

from EUSERV. <strong>Telcon</strong> generates this CENLOG.<br />

OSITS–IPM CONTINGENCY ERROR<br />

Description: An IPM contingency item was ignored. The OSITS component of the<br />

OSITS program product generates this CENLOG.<br />

Reason: The IPM contingency item contained either an erroneous or an unrecognized<br />

function code.<br />

OSITS–IPM REGISTRATION ERROR<br />

Description: Unable to register as an IPM receiver. The OSITS component of the<br />

OSITS program product generates this CENLOG.<br />

Reason: IPM receive registration failed.<br />

7436 0728–303 13–75