Event 9 INVALID RUN TIME TABLE ACCESS<br />

UDLCRS<br />

Description: R8: 0006. AE$UD032: (UDLC). BAD CONTROL MESSAGE FROM IOP:<br />

MP$GF/MP$DF INVALID.<br />

The contents of the MP$GF field or the MP$DF field of the MPA are invalid. The MPA<br />

is built by a port processor in an MCT. The function indicated by the MP$FX field is<br />

performed by the procedure identified by the MP$SEG field. <strong>Telcon</strong> generates this<br />

CENLOG.<br />

X.25 SNMP: Unable to load PDNSVS init. segment ("procedure<br />

name")<br />

Description: The X.25 PSCS SNMP interface module (PDNSMP) encountered an<br />

unexpected processing error. PDNSMP was unable to access a run-time table central<br />

to accessing X.25 MIB information. This adversely affects the ability of X.25-related<br />

MIB information from being retrieved by the SNMP management workstation.<br />

R8: Run-time address of the PDNSVS initialization segment<br />

Attributes affected: Recoverable error event, supplementary text message.<br />

Action: This event indicates an internal software interface error. You may have to<br />

re-start your <strong>Telcon</strong> run in order to recover from this error. If the error re-occurs, take<br />

a <strong>Telcon</strong> dump and submit a UCF. Procedure: The procedure name, which is internal<br />

to the X.25 PSCS PDNSMP module, is displayed as part of the supplementary text<br />

message.<br />