Event 11 ILM EVENT<br />

ENET (016): Can't queue bridge MAC frame (discarded)<br />

Description: The host channel on the HLB is not operational after a successful XID<br />

exchange. All input frames to the HLB are discarded. The Ethernet link provider<br />

interface application (LPIA) for the ILM software generates this CENLOG.<br />

ENET (017): Can't queue loopback input frame (discarded)<br />

Description: ILM software error. ILM loop-back (LOOP command) test failed. The<br />

Ethernet link provider interface application (LPIA) for the ILM software generates this<br />

CENLOG.<br />

ENET (018): HLE output received - LCC disabled (discarded)<br />

Description: INTEL 825x6 LAN Chip Controller (LCC) hardware failure. ILM is not<br />

usable. The Ethernet link provider interface application (LPIA) for the ILM software<br />

generates this CENLOG.<br />

ENET (019): SAI Down received from bridge<br />

Description: The host channel on the HLB is down. The Ethernet link provider<br />

interface application (LPIA) for the ILM software generates this CENLOG.<br />

ENET (020): SAI Up received from bridge<br />

Description: The host channel on the HLB is up. The Ethernet link provider<br />

interface application (LPIA) for the ILM software generates this CENLOG.<br />

ENET (022): Bridge output frame too short (discarded)<br />

Description: The length of an HLB output frame is less than the required packet<br />

header. The Ethernet link provider interface application (LPIA) for the ILM software<br />

generates this CENLOG.<br />

ENET (023): Can't queue XID response to bridge<br />

Description: The input side of the HLB is not operational. All input frames to the<br />

HLB are discarded. The Ethernet link provider interface application (LPIA) for the<br />

ILM software generates this CENLOG.<br />

ENET (024): XID response queued to bridge<br />

Description: The HLB is operational. A long CENLOG shows the XID. The Ethernet<br />

link provider interface application (LPIA) for the ILM software generates this<br />

CENLOG.<br />