Event 8 ABNORMAL LINE TERMINATION FUNCTION<br />

NTRLPH<br />

Description: This event occurs if an NTR site is terminated abnormally. The<br />

supplemental message identifies the source of the abnormal termination. The NTR<br />

site is signed off, with any active output files being requeued. If any input device is<br />

active when this occurs, all of the input file is discarded. The LINE/SITE DOWNED, or<br />

RE-SIGNON case need not be investigated further. The FATAL INPUT/OUTPUT<br />

ERROR case should be investigated for a possible hardware problem, as should the<br />

MAX OUTPUT RETRY case. The NO RESPONSE or NAK-SEQ OVERFLOW cases<br />

indicate that the <strong>DCP</strong> cannot communicate with the remote site either because of a<br />

hardware problem, or because the remote site has crashed or has hardware problems<br />

of its own. The NAK-LOOP case indicates that the same message is being affected by<br />

NAK, but the recovery process is working without any hardware error. This is usually<br />

caused by a configuration error (wrong buffer sizes), or a protocol handling error in<br />

the software. Any preceding recoverable error CENLOGs should also be examined for<br />

any of these cases. Other information logged:<br />

R9: Nak-1 detail code<br />

01 <strong>Message</strong> too long<br />

02 <strong>Message</strong> too short<br />

03 Input message timeout<br />

04 <strong>Message</strong>-number sequence error<br />

05 Response time-out (idle-site handshake)<br />

07 Parity/LRC error<br />

08 First character not SON or S<br />

R10:<br />

0A Input overrun/output underrun<br />

0C No buffer for input<br />

0D Too many inputs without ACKing outstanding output<br />

0E Wrong FDX/HDX sign on for line configuration<br />

The active device counts word (NS$ADC) from the SCT<br />

R12: The NS$STAT1 flag word from the SCT<br />

R13: The NS$STAT2 flag word from the SCT. All NS$ equates are defined in<br />

AANTRDEF.<br />

<strong>Telcon</strong> generates this CENLOG.<br />

14–16 7436 0728–303