TRNG (061): Station removed from Ring - xxxx<br />

where xxxx is:<br />

Unknown H/W problem<br />

H/W invalid XOP<br />

H/W invalid E-int’rupt<br />

H/W invalid interrupt<br />

Unknown H/W problem<br />

H/W ring underrun<br />

H/W RAM parity error<br />

H/W RAM data error<br />

Unknown H/W problem<br />

Unknown H/W problem<br />

Unknown H/W problem<br />

H/W parity error<br />

H/W illegal Op-code<br />

H/W DMA write abort<br />

H/W DMA read abort<br />

H/W DIO parity error<br />

Event 6 SESSION TERMINATION COMPLETED<br />

Description: <strong>Message</strong> discarded. Informational/Hardware.<br />

Action: If problem persists, submit a UCF with a dump of the ILM.<br />

TRNG (062): Can’t insert Station into Ring - H/W lobe cable<br />

Description: Line is not operational. Hardware error.<br />

Action: Correct lobe error.<br />

TRNG (063): Can’t insert Station into Ring - Auto removal error<br />

Description: Line is not operational. Informational only.<br />

Action: None.<br />

TRNG (064): Can’t insert Station into Ring - Remove MAC frame<br />

received<br />

Description: Line is not operational. Informational only.<br />

Action: None.<br />