ENET (041): LCC H/W deadlocked (warning)<br />

Event 11 ILM EVENT<br />

Description: INTEL 825x6 internal lock up. ILM is temporarily not usable. The<br />

Ethernet link provider interface application (LPIA) for the ILM software generates this<br />

CENLOG.<br />

Action: ILM software will attempt a H/W RESET to restart the 825x6. A long<br />

CENLOG shows the H/W System Control Block (SCB).<br />

ENET (042): ISR - can't configure LCC H/W (FATAL!)<br />

Description: INTEL 825x6 internal failure. ILM is not usable. The Ethernet link<br />

provider interface application (LPIA) for the ILM software generates this CENLOG.<br />

Action: A long CENLOG shows the H/W Command Block (CB).<br />

ENET (043): ISR - can't set LCC H/W MAC address (FATAL!)<br />

Description: INTEL 825x6 internal failure. Set local station MAC address command<br />

failed. ILM is not usable. The Ethernet link provider interface application (LPIA) for<br />

the ILM software generates this CENLOG.<br />

Action: A long CENLOG shows the H/W Command Block (CB).<br />

ENET (044): ISR - can't set LCC H/W M/C addresses (FATAL!)<br />

Description: INTEL 825x6 internal failure. Set multicast (M/C) address command<br />

failed. ILM is not usable. The Ethernet link provider interface application (LPIA) for<br />

the ILM software generates this CENLOG.<br />

Action: A long CENLOG shows the H/W Command Block (CB).<br />

ENET (045): LCC H/W deadlock - H/W reset failed (FATAL!)<br />

Description: INTEL 825x6 internal failure. Hardware RESET did not clear LCC<br />

internal lock up. ILM is not usable. The Ethernet link provider interface application<br />

(LPIA) for the ILM software generates this CENLOG.<br />

Action: A long CENLOG shows the H/W System Control Block (SCB).<br />

ENET (046): SAI Up signal sent to HLE<br />

Description: HLE data path is available. The Ethernet link provider interface<br />

application (LPIA) for the ILM software generates this CENLOG.<br />

Action: None (informational).<br />