IP: SUBNET MISSING LOCAL ADDRESS - ADR = !<br />

Event 12 TCP–IP GATEWAY EVENT<br />

Description: TCP–IP Stack detected a configuration error. No IPADR statement was<br />

found to configure an IP address associated with the indicated SUBNET statement<br />

with the LOCAL flag. Some configured functions may not be available. The TCP–IP<br />

Stack program product generates this CENLOG.<br />

Action: Verify that the IP addresses and masks are specified correctly. Verify that<br />

the IP address assigned to TCP–IP Stack for the indicated SUBNET statement is<br />

indicated by the LOCAL flag on the IPADDR1 or IPADDR2 parameter.<br />

IP: SUBNET STATEMENT ERROR<br />

Description: IP detected an error in a SUBNET configuration statement. The<br />

TCP–IP Stack program product generates this CENLOG.<br />

IP: TCP–IP NOT CONFIGURED – DISCARDING INPUT<br />

Description: IP is receiving messages, even though no IPADR or SUBNET<br />

statements were processed. The TCP–IP Stack program product generates this<br />

CENLOG.<br />

IP: TCP–IP STACK CONNECTED TO ILM IP ROUTER<br />

Description: TCP–IP Stack is establishing communications with other software<br />

components. This message is informational only. The TCP–IP Stack program product<br />

generates this CENLOG.<br />

IP: TCP–IP STACK DISCONNECTED FROM ILM IP ROUTER<br />

Description: TCP–IP Stack has lost communications with other software<br />

components. The TCP–IP Stack program product generates this CENLOG.<br />

Action: Verify that all software components are running as needed. If the condition<br />

persists, contact your support center.<br />

IP: TIMER RETRY COUNT EXHAUSTED<br />

Description: IP repeatedly attempted to set a timer and lack of resources prevented<br />

successful completion. This event usually precedes another timer-related event. If<br />

this event occurs frequently, recheck your sizing requirements. The TCP–IP Stack<br />

program product generates this CENLOG.<br />

IP: TRACE - ARP CTL MSG<br />

Description: Informational only message. Usually indicates changes in interface<br />

state.<br />

7436 0728–303 3–47