Event 11 ILM EVENT<br />

SNMP 103 Auth fail IP=xxxxxxxx, community=ssssssss<br />

Description: The community name in a PDU from a management station was either<br />

not found in the list of configured community names, or a SET Request was received<br />

and the community name was not configured to allow SETs.<br />

Variable: xxxxxxxx The IP address of the management station from which the PDU<br />

was received, in 32-bit hex format.<br />

Variable: ssssssss The community name received from that management station.<br />

Action: The SNMP Agent and the management station must be configured to use the<br />

same community names. These names are case sensitive. Check the community and<br />

communitySET configuration statements for the SNMP Agent. Refer to the ENS<br />

Installation, Configuration, and Operations Guide (7441 2065), for a detailed<br />

description and options for these statements.<br />

In some cases an unauthorized management station trys to gain access to the SNMP<br />

Agent. In this case the CENLOG indicates that an unauthorized access has been<br />

attempted, and the CENLOG can be ignored.<br />

SNMP 104 Auth failure and not enabled<br />

Description: Indicates that the SNMP Agent wanted to send an authentication failure<br />

trap PDU to a management station, but that the sending of these traps was not<br />

enabled in the SNMP Agent’s configuration.<br />

Action: Authentication failure traps are enabled by the snmpEnableAuthenTraps<br />

statement in the SNMP Agent’s configuration. If you enable authentication failure<br />

traps, this CENLOG does not occur.<br />

SNMP 105 Bad ASN.1 parse<br />

Description: The length of a PDU from a management station, that is contained<br />

within the PDU, is longer than the actual PDU received. The PDU is discarded.<br />

Action: Single occurrences can be ignored. This indicates an error in the PDU<br />

building code in the management station. An SNMP trace with TYPE=M can be used<br />

to capture the offending management PDU.<br />

SNMP 106 Bad authentication header<br />

Description: A message was received by the SNMP Agent which did not have the<br />

format of an SNMP PDU. The message is discarded.<br />

Action: If this CENLOG occurs repeatedly, an SNMP trace with TYPE=M can be used<br />

to capture the offending message.<br />