Event 2 EVENT/ERROR DETECTED AT L2 (LINK)<br />

UDLCRS<br />

Description: R8: 003C. AE$UD332. (UDLC): IS-->LDS. DM RECEIVED; LOGICAL<br />

DISCONNECT. The local station entered LDS from IS because it received a DM.<br />

<strong>Telcon</strong> generates this CENLOG.<br />

UDLCRS<br />

Description: R8: 003D. AE$UD200. (UDLC): LDS-->ITS. UA RESP. TO A MODE SET;<br />

LOGICAL CONNECTION. The local station entered ITS from LDS or IS because it<br />

received a MODE SET command (combined or secondary station) or a UA response to<br />

a MODE SET command (primary station). The following categories of event codes<br />

specify device events: The device is a UDLC station as defined by a <strong>Telcon</strong> station<br />

configuration statement. 112–120: station state change between the logical<br />

disconnect state and the information transfer state. 167–170: station state change<br />

between the initialization state and either the logical disconnect state or the<br />

information transfer state. 100, 122–130, 192: a station-level event that does not affect<br />

the state of the station.<br />

R8: Contents of the SC$SW1 field in the SCB. The SC$ equates are defined in<br />

AAHARDEF. The contents of SC$SW1 are extracted prior to making any<br />

changes required by the event.<br />

R9: Contents of the SC$SW2 field in the SCB. The SC$ equates are defined in<br />

AAHARDEF. The contents of SC$SW2 are extracted prior to making any<br />

changes required by the event.<br />

R10: Contents of the SC$STM field in the SCB. The SC$ equates are defined in<br />

AAHARDEF.<br />

For FRMR related events 99, 117, 118, R10 contains the reason for the FRMR.<br />

These reasons are specified by one or more of the following bits being set in<br />

R10.<br />

Bit 0: Bit 0 is the least significant bit. The control field contained in R15 is<br />

invalid or not implemented.<br />

Bit 1: The control field contained in R15 was considered invalid because the<br />

frame contained an information field that is not permitted with this<br />

frame.<br />

Bit 2: The received information field exceeded the maximum established<br />

capacity of the secondary/combined station.<br />

Bit 3: The control field contained in R15 contained an invalid N(R) number.<br />

R11: LCB address.<br />

R12: Pseudo TCB address so that the STE index to the station information table<br />

can be supplied as though it were the STE index to the terminal information<br />

table.<br />

R13: Control field of the frame received by the local station at the time the event<br />

occurred.<br />

For FRMR related events 99,117,118, R13 contains the third and fourth bytes<br />

of the FRMR information field.<br />