Event 2 MODIFICATION IN NODE NETWORK CONNECTION<br />

Event 2 MODIFICATION IN NODE NETWORK<br />

CONNECTION<br />

MODIFICATION IN <strong>DCP</strong> NETWORK CONNECTION<br />

Description: Network address in UDM state. <strong>Telcon</strong> generates this CENLOG.<br />

Action: Register 10 in the long format shows the <strong>Telcon</strong> node that is in a UDM state.<br />

Verify that this <strong>Telcon</strong> node is in fact down, and that it is not just a connection<br />

(TRUNK) problem.<br />

Supplementary <strong>Message</strong>s For Class 11, Event 02<br />

DUC<br />

Description: Invalid N/C name received no more DS$SEG. <strong>Telcon</strong> generates this<br />

CENLOG.<br />

INVALID N/C NAME RECEIVED<br />

Description: During the DUC initialization, a SESSN configuration statement name<br />

was received, but did not belong in the processor. <strong>Telcon</strong> generates this CENLOG.<br />

Action: The long format shows the buffer received with the SESSN statement<br />

configuration name. Check the configuration for errors.<br />

TOO MANY SESSIONS CONFIGURED•SEE AC$SESSN<br />

Description: The number of DUC-to-DUC sessions exceeds the maximum number<br />

allowed in the system. <strong>Telcon</strong> generates this CENLOG.<br />

Action: Increase the AC$SESSN value by using a NEWCON SGS and regenerate the<br />

configuration.<br />