Event 10 RESILIENCY EVENT NOTIFICATION<br />

Event 10 RESILIENCY EVENT NOTIFICATION<br />

Resiliency Event Notification<br />

Description: This CENLOG provides information about a resilient SRC switch that<br />

has occurred. <strong>Telcon</strong> generates this CENLOG.<br />

Action: The following items should be investigated by the system analyst or<br />

customer engineer to determine the cause of the problem:<br />

• CENLOG supplementary message<br />

• <strong>Telcon</strong> configuration<br />

• <strong>DCP</strong> and related hardware<br />

• <strong>Telcon</strong> dump<br />

Supplementary <strong>Message</strong>s for Class 11, Event 10<br />

HB Receive Timer Timeout<br />

Description: SRC has sent a heartbeat to the alternate <strong>Telcon</strong> in a resilient<br />

environment. A heartbeat has not been returned in the allotted amount of time.<br />

Action: SRC issues a resume heartbeat command. If the resume fails, then the cause<br />

of the inability of the two <strong>Telcon</strong>s to communicate needs to be determined.<br />

Switch/Status-Confirm Timer Timeout<br />

Description: A resilient SRC switch is in progress but the switch did not complete in<br />

the allotted amount of time.<br />

Action: The cause of the switch failure needs to be determined.<br />