Event 11 ILM EVENT<br />

LMMGT (007): Last load block received<br />

Description: Program load last block received. The line module’s ILM Platform<br />

manager generates this CENLOG.<br />

LMMGT (008): First (w/spawn) load block received<br />

Description: Program load in progress, first block received. The line module’s ILM<br />

Platform manager generates this CENLOG.<br />

LMMGT (009): Unrecognizable load code<br />

Description: An unrecognizable load code was received during the load process.<br />

The line module’s ILM Platform manager generates this CENLOG.<br />

LMMGT (010): Load complete<br />

Description: The program load completed. The line module’s ILM Platform manager<br />

generates this CENLOG.<br />

LMMGT (011): Input detach request in OAT range<br />

Description: An invalid detach request was received. The line module’s ILM<br />

Platform manager generates this CENLOG.<br />

LMMGT (012): No IUT entry for requested AID for the ILM software.<br />

Description: The ILM Platform manager received a request for an attach ID for<br />

which there is no Interface User Table (IUT) entry. The request cannot be honored.<br />

(Software error.) This CENLOG is generated by the line module’s ILM Platform<br />

manager.<br />

LMMGT (013): 'AID' for output is greater min input ID<br />

Description: The ILM Platform manager received an invalid output attach request.<br />

(Software error.) This CENLOG is generated by the line module’s ILM Platform<br />

manager.<br />

LMMGT (014): No IUT entry for detach<br />

Description: The ILM Platform manager received a request for an attach ID for<br />

which there is no Interface User Table (IUT) entry. The request cannot be honored.<br />

(Software error.) This CENLOG is generated by the line module’s ILM Platform<br />

manager.<br />