30.01.2013 Views

DCP Series Telcon Message Manual - Public Support Login - Unisys

DCP Series Telcon Message Manual - Public Support Login - Unisys

DCP Series Telcon Message Manual - Public Support Login - Unisys

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Event 3 EVENT/ERROR DETECTED AT L3 (NETWORK)<br />

CFACCS WEIRD ERROR (R8)<br />

Description: The PDNDXA module received an unknown error from a CALL<br />

reference to CFACCS.<br />

R8: Error code returned by CFACCS<br />

Attributes affected: Error event, Configuration event. The X.25 PSCS program<br />

product generates this CENLOG. Procedure: TPCDATA.<br />

DCA TERMINAL NOT CONFIGURED<br />

Description: The PDNDXA module cannot obtain one of its DTE TS table entries<br />

based upon the TSID passed in an output data message buffer. The software has<br />

either corrupted the routine in TSTN that puts the TSID into the message buffer or the<br />

routine in PDNDXA used to obtain the DTE TS table.<br />

Attributes affected: Error event. The X.25 PSCS program product generates this<br />

CENLOG. Procedure: TPCDATA.<br />

DCATS AND DTE DONT PAIR<br />

Description: The PDNDXA module obtained a DTE statement that contains an STE<br />

index of a DCATS statement, but the DCATS statement does not contain the<br />

corresponding STE index of the DTE statement. (Statements don’t point to each<br />

other.) This DCATS/DTE statements pair is ignored.<br />

Attributes affected: Error event, Configuration event. The X.25 PSCS program<br />

product generates this CENLOG. Procedure: TPCDATA.<br />

DCATS NOT PAIRED WITH DTE<br />

Description: The PDNDXA module was unable to obtain a DTE STE using<br />

information from a DCATS statement. The DCATS statement does not point to a DTE<br />

type statement. The DCATS statement is ignored.<br />

Attributes affected: Error event, Configuration event. The X.25 PSCS program<br />

product generates this CENLOG. Procedure: TPCDATA.<br />

DNS: NEIGHBOR NETWRK VERSN NAME MISMATCH, NA = node<br />

address<br />

Description: Neighbor node with the node address displayed in the supplementary<br />

message is using a configuration that contains a network version name that is<br />

different from the network version name contained in this node’s configuration.<br />

<strong>Telcon</strong> generates this CENLOG.<br />

Action: None. This CENLOG is displayed to inform you that both nodes are using<br />

configurations created for different network levels.<br />

13–12 7436 0728–303

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!