Event 11 ILM EVENT<br />

ILMX25 Line Already Up<br />

Description: PDNILM received a line initialization packet from the ILM Platform for<br />

a port that already has an enabled line (a line control block already exists).<br />

Attributes affected: Line event including port number and line name,<br />

supplementary text message. Procedure line_init_request of the X.25 PSCS program<br />

product generates this CENLOG.<br />

Action: Check the <strong>Telcon</strong> configuration for duplicate port addresses on the LINE<br />

configuration statement of the ADR parameter.<br />

ILMX25 Line Control Block Build/Initialization Failure<br />

Description: During X.25 line initialization, <strong>DCP</strong> OS buffer resource problems<br />

occurred while trying to reserve system segment numbers or allocate buffer space for<br />

the line control block.<br />

Attributes affected: Line event including the port number and line name,<br />

supplementary text message. Procedure line_init_request of the X.25 PSCS program<br />

product generates this CENLOG.<br />

Action: Either the <strong>DCP</strong> itself has temporarily run out of memory (become throttled),<br />

or <strong>Telcon</strong> or the OS have reached configured buffer limits. Check to see if the<br />

configured buffer limits are too low.<br />

ILMX25 Line Initialization Failure<br />

Description: An error occured during X.25 line initialization. The specific reason is<br />

reported in one of the following related CENLOGs.<br />

• Class 5 Event 15 “X.25 PSCS Initialization error” may be reported indicating a<br />

probable configuration error. Refer to the CENLOG’s description for the specific<br />

initialization error.<br />

• A Configure Element Confirm packet was received from the ILM Platform<br />

containing a failure status. Another CENLOG should be reported by the ILM<br />

Platform or ILM IA indicating the reason for the failure.<br />

Attributes affected: Line event including the port number and line name,<br />

supplementary text message. Procedure line_init_request of the X.25 PSCS program<br />

product generates this CENLOG.<br />

Action: Refer to any other “initialization error” CENLOGs related to this one for<br />

determining the reason for the error. If no other CENLOGs occurred, this may<br />

indicate a software error. Contact your <strong>Unisys</strong> support representative.<br />