Event 1 PROGRAM PRODUCT NOT PRESENT<br />

PDNLPD<br />

Description: The X.25 PSCS NMS terminal processing nonfunctional module<br />

(PDNLPD) received an NMS command. Because X.25 PSCS is not installed, it is<br />

unable to process the NMS command.<br />

Attributes affected: Configuration event. The nonfunctional PDNLPD module in<br />

<strong>Telcon</strong> for the X.25 PSCS program product generates this CENLOG. Procedure:<br />

PDNLPD.<br />

Action: Install the X.25 PSCS program product, or remove the TERM statement<br />

associated with X.25 PSCS.<br />

PDNMAS<br />

Description: The X.25 PSCS NMS line processing nonfunctional module (PDNMS)<br />

received an NMS STAT or LIST LINE command. Because X.25 PSCS is not installed,<br />

it is unable to process the NMS command.<br />

Attributes affected: Configuration event. The nonfunctional PDNMS module in<br />

<strong>Telcon</strong> for the X.25 PSCS program product generates this CENLOG. Procedure:<br />

PDNMAS.<br />

Action: Install the X.25 PSCS program product, or modify the LINE statement<br />

associated with X.25 PSCS.<br />

PDNNET - EU NDS ENCOUNTERED<br />

Description: The X.25 PSCS DCE Network feature’s nonfunctional module<br />

(PDNNET) received an EU statement information table. Because X.25 PSCS is not<br />

installed, it is unable to process the EU statement information.<br />

Attributes affected: Supplementary text message. Error event. The nonfunctional<br />

PDNNET module in <strong>Telcon</strong> for the X.25 PSCS program product generates this<br />

CENLOG. Procedure: PDNETP.<br />

Action: Install the X.25 PSCS program product or modify the EU statement with the<br />

TYPE=<strong>DCP</strong>NET parameter.<br />