Event 6 SESSION TERMINATION COMPLETED<br />

TRNG (065): Can’t insert Station into Ring - xxxx<br />

where xxxx is:<br />

Unknown H/W problem<br />

H/W invalid XOP<br />

H/W invalid E-int’rupt<br />

H/W invalid interrupt<br />

Unknown H/W problem<br />

H/W ring underrun<br />

H/W RAM parity error<br />

H/W RAM data error<br />

Unknown H/W problem<br />

Unknown H/W problem<br />

Unknown H/W problem<br />

H/W parity error<br />

H/W illegal Op-code<br />

H/W DMA write abort<br />

H/W DMA read abort<br />

H/W DIO parity error<br />

Description: <strong>Message</strong> discarded. Informational/Hardware.<br />

Action: If problem persists, submit a UCF with a dump of the ILM.<br />

TRNG (066): SAI Up signal sent to HLE<br />

Description: Connection is going active. Informational only.<br />

Action: None.<br />

TRNG (067): SAI Down signal sent to HLE<br />

Description: Connection is going active.<br />

Action: None.<br />

TRNG (068): Set multicast address request received<br />

Description: Multicast address will be filtered by LPIA.<br />

Action: None.<br />

TRNG (069): Input frame has incorrect RIF length<br />

Description: <strong>Message</strong> discarded. <strong>Message</strong> error.<br />

Action: None.<br />