Event 2 EVENT/ERROR DETECTED AT L2 (LINK)<br />

Event 2 EVENT/ERROR DETECTED AT L2 (LINK)<br />

EVENT/ERROR DETECTED AT L2 (LINK)<br />

Description: A procedure that transfers information across a physical link detected<br />

an error. Such errors may be either recoverable or fatal. For fatal errors, a system<br />

dump may be initiated or the procedure may be blocked. <strong>Telcon</strong> generates this<br />

CENLOG.<br />

Action: This may be a symptom of problems of a particular physical link the user<br />

encountered. This message may signal the operator to take a system dump when<br />

attempting to trap such a problem. Frequent occurrences of such errors/events may<br />

indicate that corrective action should be taken.<br />

ALPMCP<br />

Description: The ASYNCH link service has detected a software error. The error<br />

severity code is in R10, and the error code (6Fxx) is in R11. Severity codes are as<br />

follows: 0 = fatal, 1 = serious, 2, 3, 4 = trivial. <strong>Telcon</strong> generates this CENLOG.<br />

ASYNMLCP<br />

Description: The ASYNCH link service has detected an input error.<br />

R8 = 0024<br />

R9 = 8000 No buffer - the port processor could not obtain a buffer for message<br />

4000 Input limit - more input came in that there is buffer space<br />

0400 <strong>Message</strong> timeout - input came in without an end of message character<br />

0200 DSR off - data set ready has been dropped and the line will disconnect<br />

0100 Parity error - configured line speed, parity or character length does not<br />

match what the hardware or software in PC is set up to<br />

0040 Data overrun - the port processor cannot keep up with the rate at which<br />

the input is being received<br />

PDNSVS<br />

Description: The X.25 line initialization module (PDNSVS) was unable to successfully<br />

complete the connection of an enabled line. This event includes the LINE name.<br />

R15: Error reason code<br />

Attributes affected: Line event, Configuration event, Line Control Block (LCB)<br />

address in register R11. The X.25 PSCS program product generates this CENLOG.<br />

Procedure: PDNSVS.<br />

7436 0728–303 13–3