IP: UNABLE TO SEND BROADCAST MSG OVER X.25<br />

Event 12 TCP–IP GATEWAY EVENT<br />

Description: An upper layer attempted to send a broadcast message through a DDN<br />

or generic X.25 layer. The TCP–IP Stack program product generates this CENLOG.<br />

IP: UNRECOG SUBNET TYPE<br />

Description: IP found a SUBNET configuration of an unrecognized TYPE. The TCP–<br />

IP Stack program product generates this CENLOG.<br />

IP: UNRECOGNIZED CONFIG ITEM<br />

Description: IP was called for initialization and the configuration item passed was<br />

not recognized. This error indicates a software failure on the part of the initialization<br />

module. This is not a serious condition. The TCP–IP Stack program product<br />

generates this CENLOG.<br />

IP: UNRECOGNIZED OPTION RECEIVED<br />

Description: IP received an IP option that was not implemented. Another host with<br />

TCP–IP could be having problems. The TCP–IP Stack program product generates this<br />

CENLOG.<br />

IP: UNSOLICITED PING REPLY<br />

Description: TCP–IP Stack received an unexpected message or too much time<br />

elapsed before receiving an expected message. This error is normally recoverable.<br />

The TCP–IP Stack program product generates this CENLOG.<br />

Action: Increase the amount of time specified by the TIMEOUT parameter in the<br />

NMS command TCP PING. If the condition persists, contact your support center.<br />

IP: UNSUPPORTED OPTION RECEIVED<br />

Description: The security stream ID and timestamp options are not supported at this<br />

time. The TCP–IP Stack program product generates this CENLOG.<br />

IP: X.25 NETWORK CONNECTIONS DOWN (R8, R9)<br />

Description: PSCS informed IP that the link is not available for data. The TCP–IP<br />

Stack program product generates this CENLOG.<br />

IP: X.25 NETWORK CONNECTIONS UP (R8, R9)<br />

Description: PSCS informed IP that the link is available for data. The TCP–IP Stack<br />

program product generates this CENLOG.<br />