DTE VC WASNT LOADED<br />

Event 3 EVENT/ERROR DETECTED AT L3 (NETWORK)<br />

Description: The PDNDXA module received an NMS DOWN PDTE indication<br />

primitive, but was unable to associate a DTE virtual circuit table based upon the DTE<br />

address passed by the primitive. A software error has corrupted the DTE address<br />

passed in the primitive.<br />

Attributes affected: Fatal error event. The X.25 PSCS program product generates<br />

this CENLOG. Procedure: TPCDATA.<br />

DTETS TBL NOT BUILT<br />

Description: The PDNDXA module was unable to successfully build a DTE TS table<br />

entry using information obtained from the DCATS statement. A software error has<br />

either corrupted the DCATS STE or the routine that builds DTE TS tables.<br />

Attributes affected: Error event, Configuration event. The X.25 PSCS program<br />

product generates this CENLOG. Procedure: TPCDATA.<br />

DTEVC HAS NO LSCH LIST<br />

Description: The PDNDXA module cannot successfully associate one of its DTE<br />

virtual circuit tables with a logical subchannel table entry. A software error has<br />

corrupted the logical subchannel table entry addresses within the DTE virtual circuit<br />

tables.<br />

Attributes affected: Fatal error event. The X.25 PSCS program product generates<br />

this CENLOG. Procedure: TPCDATA.<br />

INVALID DTETS LOG ADR<br />

Description: The PDNDXA module was unable to associate one of its TSID table<br />

entries from an address obtained from its DTE virtual circuit table. A software error<br />

has corrupted the TSID address in the DTE virtual circuit table.<br />

Attributes affected: Fatal error event. The X.25 PSCS program product generates<br />

this CENLOG. Procedure: TPCDATA.<br />

INVALID DTEVC LOG ADR<br />

Description: The PDNDXA module cannot obtain the DTE VC table entry using an<br />

address from the logical subchannel table entry. A software error has corrupted one<br />

of the DTE VC table entry addresses in one of the logical subchannel table entries.<br />

Attributes affected: Fatal error event. The X.25 PSCS program product generates<br />

this CENLOG. Procedure: TPCDATA.<br />

7436 0728–303 13–13