HCC<br />

Event 4 PORT PROCESSOR (PP) SPECIFICATION EXCEPTION<br />

Description: HCC has received a state-item from a host channel port. If the stateitem<br />

was due to an NMS DOWN command, the port is freed and the facility is marked<br />

as down. If the state-item was due to a software or hardware error, an attempt is<br />

made to restart the port.<br />

R8: Current instruction offset in HCC<br />

R9: TSID<br />

R10: Port output chain address<br />

R11: Port input chain address<br />

R12: Op-code of instruction that errored: bits 15-8<br />

Type of error: bits 7-5<br />

R13:<br />

Subtype of error: bits 4-0<br />

Supplementary status<br />

R14: PPID<br />

R15: Input flags from AGSYSRTN<br />

<strong>Telcon</strong> generates this CENLOG.<br />

NTRLPH<br />

Description: This event occurs whenever the PP hardware or the PP program<br />

detects a fatal hardware or software error. The line is brought down after occurrence<br />

of this event. If the error type and subtype (logged registers R9 & R10) do not indicate<br />

a hardware error, this information should be the basis for submission of a UCF. Other<br />

information logged:<br />

R9: Error type code<br />

R10: Error sub-type code<br />

R12: Output chain execution address<br />

R13: Input chain execution address<br />

R14: PP-D. Values in other registers may be useful for debug. The PP state-item<br />

buffer is logged in the first 64 (X'40') words. The LCB and SCT (site control<br />

table) are logged in the remaining words of the log entry.<br />

<strong>Telcon</strong> generates this CENLOG.<br />

RMLPH<br />

Description: Port hung; Unable to force state-item by clearing the ‘C’ bit; but, the<br />

state-item was never received. This is a hardware or microcode problem.<br />

R15: Port number<br />

<strong>Telcon</strong> generates this CENLOG.<br />

7436 0728–303 7–7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!