Event 7 EVENT/ERROR DETECTED AT L7 (APPLICATION)<br />

Event 7 EVENT/ERROR DETECTED AT L7<br />

(APPLICATION)<br />

EVENT/ERROR DETECTED AT L7 (APPLICATION)<br />

Description: A significant event has taken place, or an error has been discovered in<br />

the DCA protocol stack layer 7, Application Layer.<br />

Action: Dependent on the supplementary (or procedure name) displayed.<br />

Supplementary <strong>Message</strong>s for Class 13, Event 07<br />

Reserved.<br />

Description: The EUAFO interface rejected an IPC message.<br />

R8, R9: Conversation identifier<br />

R11: AP class<br />

<strong>Telcon</strong> generates this CENLOG.<br />

NTRLPH<br />

Description: This event occurs if an RB-2 protocol error is detected. A supplemental<br />

message specifies the protocol error. In most cases, this results in the affected device<br />

being immediately terminated. If it is an output device, the file is requeued. If it is an<br />

input device, its file is discarded. Other information logged:<br />

R14: The line’s PP ID<br />

R15: The device’s device-number. Other registers are applicable to debug use only<br />

and are different for each case.<br />

<strong>Telcon</strong> generates this CENLOG.<br />

7436 0728–303 13–85