Event 6 SESSION TERMINATION COMPLETED<br />

TRNG (031): HLE output - no StationCB active (discarded)<br />

Description: Line is down. Internal error.<br />

Action: Submit a UCF to HLE.<br />

TRNG (033): UserIA sent invalid BH$ Control output<br />

Description: Buffer discarded. Internal error.<br />

Action: Submit a UCF to UserIA.<br />

TRNG (034): Loopback output frame too short<br />

Description: Buffer discarded. Internal error. Possible hardware error.<br />

Action: None.<br />

TRNG (035): Invalid ouput FUI/DUI RIF length<br />

Description: Buffer discarded. Internal error.<br />

Action: Submit a UCF with a type code of HLE.<br />

TRNG (036): Non-LLC HLE output (config error)<br />

Descripton: <strong>Message</strong> discarded. Configuration error.<br />

Action: Correct your HLE configuration.<br />

TRNG (043): Station inserted into Token Ring<br />

Description: Line is initialized.<br />

Action: None.<br />

TRNG (044): Can’t insert Station into Ring - Driver Init Error<br />

Description: Line is not initialized. Internal error.<br />

Action: Submit a UCF with a dump of the ILM.<br />

TRNG (045): Can’t insert Station in Ring - Two Stations have same Adr<br />

Descripton: Two or more stations on the ring have the same address.<br />

Action: Correct the station configurations.<br />

6–10 7436 0728–303