Event 15 CONFIGURATION ERROR DETECTED / UNDEFINED<br />

SYSSESN<br />

Description: Error on SESSN card — fatal.<br />

R14: Indicates type of error<br />

= 1 – Session length long, check TS1/TS2<br />

= 2 – Session length short, check TS1/TS2<br />

= 3 – CFACCS error return while building LX$ table<br />

= 4 – Bad <strong>Telcon</strong> node destination, check TS1/TS2<br />

= 7 – Duplicate logical subchannel<br />

R15: LS #<br />

<strong>Telcon</strong> generates this CENLOG.<br />

Too many digits on the PDNGRP DTEADR parameter<br />

Description: During line initialization (module PDNSVS) obtained the PDNGRP<br />

statement associated with the LINE statement that was enabled. The number of DTE<br />

address digits configured on the PDNGRP’s DTEADR parameter is greater than 14.<br />

The DTE address specified is ignored. This event includes the LINE statement name.<br />

R10: PDNGRP STE index<br />

Attributes affected: Supplementary text message, Configuration event. The X.25<br />

PSCS program product generates this CENLOG. Procedure: PDNSVS.<br />

TOO MANY SESSIONS CONFIGURED–INCREASE AC$SESSS.<br />

Description: This CENLOG refers to an error in TS/TN where it received an<br />

initialization for a SESSN that was not put into the TS/TN SS$ table. This is because<br />

the number of SESSNs configured was greater than the maximum table space<br />

available. If none of the SESSNs to the termination system were able to get into the<br />

SS$ tables, the user may have a problem getting into the termination system. The<br />

default is currently 4000 SS$ entries. The system discards this message. <strong>Telcon</strong><br />

generates this CENLOG.<br />

Action: Increase the value for AC$SESSS in AACONFIG by using the NEWCON<br />

parameter.<br />

TSTN<br />

Description: Fast path protocol has been specified in <strong>Telcon</strong>, but the host does not<br />

support it. This problem could cause <strong>Telcon</strong> to run in a loop. Check the host system<br />

release to make sure the host supports fast path protocol. <strong>Telcon</strong> generates this<br />

CENLOG.<br />

5–86 7436 0728–303