Event 11 MAXIMUM TABLE-SIZE LIMIT REACHED<br />

Event 11 MAXIMUM TABLE-SIZE LIMIT REACHED<br />

NTRLPH<br />

Description: This event occurs if the remote operator at an NTR site is attempting to<br />

start up an input device when the <strong>DCP</strong> is in a soft-throttle or hard-throttle situation, in<br />

which case the <strong>DCP</strong> does not have the resources to run the input device. In this case,<br />

the request for input device initialization is ignored, and the remote operator can retry<br />

the keyin later. This event is displayed so that the <strong>Telcon</strong> system operator can answer<br />

queries from the remote NTR operator as to why input cannot be started. If the<br />

system gets out of hard or soft throttle, input starts up normally. If this event happens<br />

frequently, changes should be made to the configuration to keep the system from<br />

running low on storage. Other information logged:<br />

R14: The PPID of the line the NTR site is on<br />

R15: The device number of the input device being denied initialization<br />

<strong>Telcon</strong> generates this CENLOG.<br />

SNMP 302 Unable to allocate peer table entry for port nn<br />

Description: This event reports the inability of an SNMP Agent to coordinate with<br />

another Agent using an ICS connection. It indicates either a lack of sufficient<br />

memory, or possibly corrupted memory.<br />

More than one SNMP Agent is loaded and configured within the same ICS domain. As<br />

each Agent initializes, it forms an ICS connection and passes coordination data<br />

messages with all other Agents so that all Agents can determine which one becomes<br />

active. Either a run time table entry could not be obtained upon receiving the ICS<br />

connection indication, or the table entry could not be obtained upon receiving a<br />

subsequent coordination message from another Agent.<br />

Variable: nn The ILM port of the SNMP Agent that initiated the ICS connection or<br />

sent the coordination message.<br />

Action: This event is related to memory limitations. Check the ILM port where the<br />

SNMP Agent is configured and choose an ILM with more memory.<br />

This event could be reported by an SNMP Agent that will not become active; it could<br />

adversely impact the Agent that is intended to become active. If memory limitations<br />

have been considered and this event is reported, dump the ILM.<br />

If no SNMP Agent is currently active, either restart ICS or reload all ILMs containing a<br />

configured SNMP Agent to recover from the problem.<br />