Event 11 ILM EVENT<br />

ENET (032): LCC H/W failed transceiver loopback (FATAL!)<br />

Description: Transceiver failure or problem with transceiver cable connection. ILM<br />

is not usable. The Ethernet link provider interface application (LPIA) for the ILM<br />

software generates this CENLOG.<br />

Action: ILM TDR command may indicate location and cause of problem.<br />

ENET (033): LCC H/W failed 'set SCP address' (FATAL!)<br />

Description: INTEL 825x6 internal failure. Initialization of LCC hardware structures<br />

failed. ILM is not usable. The Ethernet link provider interface application (LPIA) for<br />

the ILM software generates this CENLOG.<br />

Action: An ILM DUMP might indicate the cause of the failure.<br />

ENET (034): LCC H/W failed external loopback (FATAL!)<br />

Description: INTEL 825x6 internal failure. The probable cause is a short or open on<br />

the LAN cable. ILM is not usable. The Ethernet link provider interface application<br />

(LPIA) for the ILM software generates this CENLOG.<br />

Action: The ILM TDR command might indicate location and cause of the problem.<br />

ENET (036): Can't queue SAI signal to HLE (FATAL!)<br />

Description: ILM software error. ILM is not usable. The Ethernet link provider<br />

interface application (LPIA) for the ILM software generates this CENLOG.<br />

ENET (037): ISR - can't queue link input (FATAL!)<br />

Description: ILM software error. ILM is not usable. The Ethernet link provider<br />

interface application (LPIA) for the ILM software generates this CENLOG.<br />

ENET (039): Can't allocate LCC H/W SCB area (FATAL!)<br />

Description: ILM software error. ILM is not usable. The Ethernet link provider<br />

interface application (LPIA) for the ILM software generates this CENLOG.<br />

ENET (040): LCC H/W register dump taken (FATAL!)<br />

Description: INTEL 825x6 internal failure. ILM is not usable. The Ethernet link<br />

provider interface application (LPIA) for the ILM software generates this CENLOG.<br />

Action: An ILM DUMP may indicate the cause of the failure.<br />

6–56 7436 0728–303