Event 11 ILM EVENT<br />

PPP (nnn) Input frame discarded due to line error<br />

Description: An input message was received in error and discarded (nnn is an<br />

indicator of the location of the CENLOG in the PPP software).<br />

Action: If this occurs, often the quality of the link should be upgraded.<br />

PPP (nnn) Unrecoverable line error<br />

Description: The line failed (nnn is an indicator of the location of the CENLOG in<br />

the PPP software).<br />

Action: PPP tries to connect to the peer on the link again. If this occurs, often the<br />

quality of the link should be upgraded.<br />

SDLC (000): Registered with platform<br />

Description: The SDLC IA registered itself with the ILM platform and with DLCMAN.<br />

This CENLOG is generated by the SDLC link provider interface application (LPIA) for<br />

the ILM software.<br />

Action: This is a normal occurrence that requires no user action.<br />

Supplementary Data: Management Extension Registration Packet. For more<br />

information, refer to the ILM Platform Programming Reference <strong>Manual</strong> (7431 8569).<br />

SDLC (001): ABM mode not supported in this release<br />

Description: An attempt was made to configure an ABM station. ABM is not<br />

supported in this release level. This CENLOG is generated by the SDLC link provider<br />

interface application (LPIA) for the ILM software.<br />

Action: Correct the configuration.<br />

Supplementary Data: Connection Control Block. For more information, refer to the<br />

ILM Platform Programming Reference <strong>Manual</strong> (7431 8569).<br />

SDLC (003): Configuration ERROR - Incompatible stations<br />

Description: An attempt was made to configure incompatible stations on the line.<br />

This CENLOG is generated by the SDLC link provider interface application (LPIA) for<br />

the ILM software.<br />

Action: Correct the configuration.<br />

Supplementary Data: Connection Control Block. For more information, refer to the<br />

ILM Platform Programming Reference <strong>Manual</strong> (7431 8569).<br />