IP: NMS COMMAND FACILITY NOT FOUND<br />

Event 12 TCP–IP GATEWAY EVENT<br />

Description: IP received an NMS command referencing a configured facility that is<br />

not associated with IP SUBNETs. The TCP–IP Stack program product generates this<br />

CENLOG.<br />

IP: NO DTE ADDRESS FOR CALL TO NON-DDN DESTINATION - ADR = !<br />

Description: There is no IPADR configuration providing a DTEADR for this IP<br />

address (R8, R9). The TCP–IP Stack program product generates this CENLOG.<br />

IP: NO LOCAL ADDRESSES CONFIGURED<br />

Description: TCP–IP Stack detected a configuration error. No IPADR statement was<br />

found to configure an IP address with the LOCAL flag. Some configured functions<br />

may not be available. The TCP–IP Stack program product generates this CENLOG.<br />

Action: Verify that all IP addresses and masks are specified correctly. Verify that IP<br />

addresses assigned to TCP–IP Stack are indicated by the LOCAL flag on the IPADDR1<br />

or IPADDR2 parameter.<br />

IP: NO MATCHING DLCI FOR FRLY SUBNET<br />

Description: IP cannot find a DLCI statement to match the DLCI parameter for this<br />

IP address (R8, R9). The TCP–IP Stack program product generates this CENLOG.<br />

IP: NO PDNGRP FOR PSCS LINE<br />

Description: TCP–IP Stack detected a configuration error. No PDNGRP statement<br />

was found for a LINE referenced by a SUBNET statement that had the TYPE<br />

parameter set to IPPDN or DDN. Some configured functions may not be available.<br />

The TCP–IP Stack program product generates this CENLOG.<br />

Action: Verify that the SUBNET statement references the correct LINE statement.<br />

Verify that the Packet Switched Communications Software (PSCS) program product is<br />

configured correctly.<br />

IP: OPTION LIST TOO LONG, OPTION IGNORED<br />

Description: IP detected an internal error. This could indicate a serious software<br />

fault. The TCP–IP Stack program product generates this CENLOG.<br />

IP: OUTPUT LOST, OUT OF RESOURCES<br />

Description: A lack of resources caused IP to abandon an output message. This<br />

problem is not serious. Check sizing requirements to avoid this problem. The TCP–IP<br />

Stack program product generates this CENLOG.<br />