Event 6 RESILIENCY AUDIT FILE PROBLEM<br />

Event 6 RESILIENCY AUDIT FILE PROBLEM<br />

RESILIENCY AUDIT FILE PROBLEM<br />

Description: The problem occurred while building the audit file. SRC is attempting<br />

to rebuild it. <strong>Telcon</strong> generates this CENLOG.<br />

Action: Ignore if the reinitialization is successful. If the reinitialization is not<br />

successful, take a dump and reload from the host.<br />

Supplementary <strong>Message</strong>s for Class 11, Event 06<br />

SRC AUDIT FILE PROBLEM: BAD CONFIRMATION<br />

Description: A bad confirmation was received from the alternate <strong>Telcon</strong> node after<br />

sending the audit file contents. <strong>Telcon</strong> generates this CENLOG.<br />

Action: Ignore if the reinitialization is successful. If the reinitialization is not<br />

successful, take a dump and reload from the host.<br />

SRC AUDIT FILE PROBLEM: FILE COMPROMISED<br />

Description: The audit file is compromised and can no longer be trusted. <strong>Telcon</strong><br />

generates this CENLOG.<br />

Action: Dump the <strong>Telcon</strong> node when convenient and reload from the host.<br />

SRC AUDIT FILE PROBLEM: AUDIT FILE FULL<br />

SRC<br />

Description: The audit file is now full and no more information will be saved. All<br />

subsequent online configuration and NMS changes will not be sent to the backup<br />

<strong>Telcon</strong> node when the path is restored. <strong>Telcon</strong> generates this CENLOG.<br />

Action: On the next generation, you can increase the audit file size by increasing the<br />

size of AC$SRCAF in the module AACONFIG. You should take immediate action to<br />

restore communication to the backup <strong>Telcon</strong> node.<br />

Description: The problem occurred while building the audit file. SRC is attempting<br />

to rebuild it. <strong>Telcon</strong> generates this CENLOG.<br />

7436 0728–303 11–7