Event 5 NO POLL GROUP FOUND<br />

NO POLL GROUP FOUND<br />

Event 5 NO POLL GROUP FOUND<br />

Description: Input has been received from a UNISCOPE ®<br />

terminal that has an invalid<br />

RID for this line. <strong>Telcon</strong> generates this CENLOG.<br />

Action: This error is caused by a terminal responding to a poll with a RID other than<br />

its own. Take the terminal offline for repairs.<br />

INVALID RID RECEIVED FROM UNISCOPE TERMINAL<br />

Description: Input has been received from a terminal that has an invalid RID (that is,<br />

belongs to a poll group that is invalid for this line). Because a valid poll group cannot<br />

be found, R12 does not contain a valid TCB address. R8 contains the value of 00E5.<br />

UNILPH generates this CENLOG. For more information on UNILPH CENLOG entry<br />

descriptions, refer to Section 1 of this manual.<br />

Action: This error is caused by a terminal responding to a poll with a RID other than<br />

its own. Take the terminal offline and repair it. If this error occurs often enough to<br />

create intolerable overhead to the system, you can issue an NMS STOP command for<br />

the line to which the terminal is connected. When the terminal has been taken offline,<br />

issue an NMS STRT command for the line to restore normal operation.<br />

7436 0728–303 14–13