Event 6 IPP/IOP HARDWARE EVENT<br />

Event 6 IPP/IOP HARDWARE EVENT<br />

Description: R15 has code and status. This is a hardware event. <strong>Telcon</strong> generates<br />

this CENLOG.<br />

Supplementary <strong>Message</strong>s for Class 07, Event 06<br />

The following Class 7 Event 6 CENLOGs report hardware events that can occur on a<br />

<strong>DCP</strong>62X.<br />

CODE IN LOWER BYTE OF R15<br />

Description: If the lower byte of R15 contains event code 020, then the upper byte is<br />

the PPID. A port processor (PP) unexpected state-item occurred on a port not<br />

assigned to a <strong>DCP</strong>/OS run. This can occur when you issue an UP or DOWN line<br />

command.<br />

Action: Contact your <strong>Unisys</strong> representative.<br />

Description: If the lower byte of R15 contains event code 021, then the upper byte is<br />

the IOPID number and an unexpected background state-item has occurred.<br />

Action: Contact your <strong>Unisys</strong> representative.<br />

Description: If the lower byte of R15 contain an event code of 050, 052, or 053, a<br />

Control Station or MCF error has occurred.<br />

050 – The link between the Control Station and the <strong>DCP</strong> has gone through recovery<br />

because of an error detected by the MCF. The OS terminal(s) are recovered<br />

but any <strong>Telcon</strong> terminals active on the Control Station must be restarted.<br />

051 – The link between the Control Station and the <strong>DCP</strong> has gone through recovery<br />

because of an error detected by the <strong>DCP</strong>. The OS terminal(s) are recovered<br />

but any <strong>Telcon</strong> terminals active on the Control Station must be restarted.<br />

052 – The link between the MCF and the <strong>DCP</strong> has gone through recovery because of<br />

an error detected by the <strong>DCP</strong>.<br />

Action: No action is required unless these CENLOGs are repeatedly occurring, then<br />

call your <strong>Unisys</strong> representative.<br />