400D CD Not <strong>Support</strong>ed. The Change-Direction indicator was set, but is not<br />

supported.<br />

400E Reserved.<br />

Sense Data<br />

400F Incorrect Use of the Format Indicator. The Format indicator (FI) was specified<br />

incorrectly. For example, FI was set with BCI = BC or FI was not set on a DFC<br />

request.<br />

4010 Alternate Code Not <strong>Support</strong>ed. The Code Selection indicator (CSI) was set<br />

when not supported for the session.<br />

4011 Incorrect Specification of RU Category. The RU Category indicator was<br />

specified incorrectly. For example, an expedited-flow request or response was<br />

specified with RU Category indicator = FMD.<br />

4012 Incorrect Specification of request Code. The request code on a response does<br />

not match the request code on its corresponding request.<br />

4013 Incorrect Specification of (SDI, RTI). The Sense Data Included indicator (SDI)<br />

and the Response Type indicator (RTI) were not specified properly on a<br />

response. The proper value pairs are (SDI = SD, RTI = negative) and (SDI =<br />

SD, RTI = positive).<br />

4014 Incorrect Use of (DR1I, DR2I, ERI). The Definite Response 1 indicator (DR1I),<br />

Definite Response 2 indicator (DR2I), and Exception Response indicator (ERI)<br />

were specified incorrectly. For example, a SIGNAL request was not specified<br />

with DR1I = DR1, DR2I = DR2, and ERI = ER.<br />

4015 Incorrect Use of QRI. The Queued Response indicator (QRI) was specified<br />

incorrectly. For example, QRI = QR on an expedited-flow request.<br />

4016 Incorrect Use of EDI. The Enciphered Data indicator (EDI) was specified<br />

incorrectly. For example, EDI = ED on a DFC request.<br />

4017 Incorrect Use of PDI. The Padded Data indicator (PDI) was specified<br />

incorrectly. For example, PDI = PD on a DFC request.<br />

4018 Incorrect Setting of QRI with Bidder's BB. The first speaker half-session<br />

received a BB chain requesting use of a session (via LUSTAT(X'0006')), but the<br />

QRI was specified incorrectly; that is, QRI = QR.<br />

4019 Incorrect indicators with Last-In-Chain Request. A last-in-chain request has<br />

specified incompatible RH settings; for example, RQE*, CEBI = CEB, and CDI =<br />

CD.<br />

401A Reserved.<br />

through<br />

4020<br />

4021 QRI Setting in Response Different From That in Request. The QRI setting in<br />

the response differs from the QRI setting in the corresponding request.<br />