Event 15 CONFIGURATION ERROR DETECTED / UNDEFINED<br />

X.25: Unassigned LCN, R9 = lcn<br />

Description: The layer 3 module (PDNL3) was unable to successfully process a<br />

packet received from the network or directly attached DTE. The packet was received<br />

on a logical channel number that is outside the range of configured logical channel<br />

ranges. This event includes the line name.<br />

R9: Received packet’s logical channel number<br />

Attributes affected: Line event, Configuration error event, Error event,<br />

Supplementary text message. The X.25 PSCS program product generates this<br />

CENLOG.<br />

Action: Review the PDNGRP statement’s logical channel ranges specified on the<br />

VCGRP parameter. Procedure: PDNL3.<br />

X.25: Virtual Circuit Assignments<br />

Description: The layer 3 module (PDNL3) was unable to successfully process a<br />

packet received from the network or directly attached DTE. The packet was received<br />

on a logical channel number of zero (and not configured to be by specifying the<br />

X25DEF statement’s L3OPT parameter value 3), or an invalid packet was received on<br />

a configured permanent virtual circuit (PVC). This event includes the line name.<br />

R8: Received packet’s logical channel number<br />

Attributes affected: Supplementary text message. The X.25 PSCS program product<br />

generates this CENLOG.<br />

Action: Review the PDNGRP statement’s logical channel ranges specified on the<br />

VCGRP parameter. Procedure: PDNL3.<br />

X.29 SIGNON FAILED: NO TERMINAL CONFIGURED<br />

Description: The X.29 Terminal initialization module (PDNURS) was unable to<br />

successfully process a $$SON command from a terminal connected through an X.29<br />

PAD interface. The reason is because the TERM statement with which it is associated<br />

does not reference a valid PDNPAD statement. The supplementary text message is<br />

logged with this event.<br />

Attributes affected: Configuration event. The X.25 PSCS program product<br />

generates this CENLOG.<br />

Action: Review X.25 PSCS’s NDSs (configuration statements). Verify all the TERM<br />

statements for X.29 PAD terminals reference valid PDNPAD statements. Procedure:<br />

PDNURS.<br />