Event 6 SESSION TERMINATION COMPLETED<br />

TRNG (014): Can’t queue I-frame to HLE<br />

Description: Buffer discarded. Internal error.<br />

Action: Submit a UCF with a dump of the ILM.<br />

TRNG (015): Invalid LLC control field in input frame<br />

Description: <strong>Message</strong> discarded. <strong>Message</strong> error.<br />

Action: None.<br />

TRNG (017): Can’t queue Control Frame to HLE<br />

Description: Buffer discarded. Internal error.<br />

Action: Submit a UCF with a dump of the ILM.<br />

TRNG (018): Can’t queue loopback input frame<br />

Description: Buffer discarded. Internal error.<br />

Action: Submit a UCF with a dump of the ILM.<br />

TRNG (019): Non-LLC input frame discarded<br />

Description: <strong>Message</strong> discarded. <strong>Message</strong> error.<br />

Action: None.<br />

TRNG (020): Station detects ring fault - Recovering with beacon<br />

frame<br />

Description: Ring reinitializes. Hardware error.<br />

Action: None.<br />

TRNG (021): Station received beacon frame - Recovering from ring<br />

fault<br />

Description: Ring should reinitialize. Informational only.<br />

Action: None.<br />

6–8 7436 0728–303