Event 11 ILM EVENT<br />

DLCMAN (312): Requested line does not support STATIONs<br />

Description: DLCMAN received an open SAP request for a line that does not support<br />

stations. The data link control manager service module that maintains the interfaces<br />

to the link providers generates this CENLOG.<br />

DLCMAN (313): Invalid LSAP type requested<br />

Description: DLCMAN received an invalid LSAP request. The data link control<br />

manager service module that maintains the interfaces to the link providers generates<br />

this CENLOG.<br />

DLCMAN (314): Unable to allocate LSAP Control Block<br />

Description: DLCMAN is unable to allocate an LSAP CB. The request is rejected.<br />

The data link control manager service module that maintains the interfaces to the link<br />

providers generates this CENLOG.<br />

DLCMAN (315): Max Connections already active on LSAP<br />

Description: DLCMAN is unable to make a connection because the LPIA has a<br />

maximum number of connections active. The data link control manager service<br />

module that maintains the interfaces to the link providers generates this CENLOG.<br />

DLCMAN (316): No Connect Control Block space can be allocated<br />

Description: DLCMAN is unable to honor a request because no control block space<br />

can be allocated. The data link control manager service module that maintains the<br />

interfaces to the link providers generates this CENLOG.<br />

DLCMAN (317): Unrecognized User Name on usrAllocSapReq<br />

Description: DLCMAN is unable to recognize the source of a request because the<br />

name in the packet is not the registered name. The data link control manager service<br />

module that maintains the interfaces to the link providers generates this CENLOG.<br />

DLCMAN (318): Requested multi-line number out of range<br />

Description: DLCMAN received a request for an illegal line number. The data link<br />

control manager service module that maintains the interfaces to the link providers<br />

generates this CENLOG.<br />

DLCMAN (319): Requested line is not initialized<br />

Description: DLCMAN received a request for a facility that is not available. The data<br />

link control manager service module that maintains the interfaces to the link<br />

providers generates this CENLOG.<br />