Event 12 TCP–IP GATEWAY EVENT<br />

TCP 4005 NO FOREIGN SOCKET SPECIFIED<br />

Description: The ULP failed to provide the foreign socket (destination) address to<br />

which the connection is to be made. The transmission control protocol module for<br />

the TCP–IP Stack program product generates this CENLOG.<br />

TCP 4006 SECURITY/PRECEDENCE VIOLATION<br />

Description: A security or precedence conflict occurred during connection<br />

establishment. The transmission control protocol module for the TCP–IP Stack<br />

program product generates this CENLOG.<br />

TCP 4007 NETWORK FAILURE<br />

Description: Attempt to route a message failed because of a gateway failure, or<br />

because there is no network connection to the destination. Check with your network<br />

administrator. The transmission control protocol module for the TCP–IP Stack<br />

program product generates this CENLOG.<br />

TCP 4008 SERVICE FAILURE<br />

Description: The ULP service request primitive type passed by a ULP is unknown to<br />

TCP. The transmission control protocol module for the TCP–IP Stack program<br />

product generates this CENLOG.<br />

TCP 4009 ULP–REQUESTED ABORT OCCURRED<br />

Description: The local end user terminal or application closed or aborted the TCP<br />

session. Try again. The transmission control protocol module for the TCP–IP Stack<br />

program product generates this CENLOG.<br />

TCP 4010 REMOTELY–REQUESTED ABORT OCCURRED<br />

Description: The peer TCP requested the connection to be aborted. The<br />

transmission control protocol module for the TCP–IP Stack program product<br />

generates this CENLOG.<br />

TCP 4011 CONNECTION CLOSING<br />

Description: TCP received an invalid service request primitive while the connection<br />

is being closed. The transmission control protocol module for the TCP–IP Stack<br />

program product generates this CENLOG.<br />