Event 15 CONFIGURATION ERROR DETECTED / UNDEFINED<br />

LSUB #00nn IS NOT CONFIGURED FOR TS #00cc<br />

Description: This CENLOG refers to an error in DUC where it received an<br />

initialization message for a Logical Subchannel (SESSN statement) that is not<br />

configured for this <strong>DCP</strong>. The user may not be able to access a Termination System if<br />

this session that is in error is the only session to the Termination System. An Out of<br />

Order Reset is sent back to the sender. <strong>Telcon</strong> generates this CENLOG.<br />

Action: From the NMS console, determine what the TS is that is sending the<br />

message. This can be done by entering DISP TS = 00cc. Then either add a SESSN<br />

statement to the <strong>Telcon</strong> configuration to match the LSUB number or remove the<br />

configuration to match the LSUB number or remove the configuration from the TS<br />

configuration.<br />

NTRLPH<br />

Description: This event occurs if an NTR site attempts to sign on using a full-duplex<br />

site ID on a line that is configured as half-duplex. This sign-on attempt will not<br />

succeed, and repeated attempts of such a sign on are logged in the same manner.<br />

Other information is logged in the registers, but is applicable to debug only. <strong>Telcon</strong><br />

generates this CENLOG.<br />

Action: The configuration on either the remote NTR site or for the <strong>DCP</strong> line being<br />

used should be changed.<br />

NTRV2P<br />

Description: This event occurs if code in NTRV2R that has specifically been turned<br />

off by the customer (to reduce memory requirements) was actually required. This is a<br />

fatal error (to NTRV2R), resulting in the procedure being blocked or the <strong>Telcon</strong><br />

crashing. Other information is logged in the registers, but is applicable to debug only.<br />

<strong>Telcon</strong> generates this CENLOG.<br />

OSIIP–DUPLICATE DNS SUBNET<br />

Description: More than one OSISN configuration statement processed defining a<br />

DNS subnet. The OSIIP component of the OSITS program product generates this<br />

CENLOG.<br />

Reason: Configuration error.<br />

OSIIP–FWD PDU FAIL<br />

Description: A PDU could not be forwarded because the forwarding subnet is down.<br />

OSITS requested output of message with no segmentation allowed. The OSITS<br />

program product generates this CENLOG.<br />

Reason: Network failure and invalid OSITS request, respectively.<br />