Event 7 EVENT/ERROR DETECTED AT L7 (APPLICATION)<br />

NTRV2R<br />

Description: This event occurs if an RB-2 protocol error is detected. A supplemental<br />

message specifies the side (host or <strong>DCP</strong>) that detected the error. In most cases, this<br />

event results in the affected device being immediately terminated. If it is an output<br />

device, the file is requeued. If it is an input device, its file is discarded. Other<br />

registers are applicable to debug use only, and are different for each case. Other<br />

information logged:<br />

R14: The line’s PP ID<br />

R15: The device’s device number<br />

<strong>Telcon</strong> generates this CENLOG.<br />