DLCMAN (225): Unable to open Loop Input queue<br />

Event 11 ILM EVENT<br />

Description: DLCMAN is unable to open queues for loop-back testing. Loop request<br />

is denied. The data link control manager service module that maintains the interfaces<br />

to the link providers generates this CENLOG.<br />

DLCMAN (226): CLOSE Line complete<br />

Description: DLCMAN indicated that the line facility close is complete. The data<br />

link control manager service module that maintains the interfaces to the link<br />

providers generates this CENLOG.<br />

DLCMAN (227): Requested LPIA not registered<br />

Description: DLCMAN received a command for which there is no target IA. The<br />

command is rejected. The data link control manager service module that maintains<br />

the interfaces to the link providers generates this CENLOG.<br />

DLCMAN (228): CLOSE Line pending<br />

Description: DLCMAN forwarded a down line request to the appropriate LPIA. The<br />

data link control manager service module that maintains the interfaces to the link<br />

providers generates this CENLOG.<br />

DLCMAN (229): CLOSE Line complete<br />

Description: DLCMAN received confirmation from an LPIA indicating line down<br />

processing is complete. The data link control manager service module that maintains<br />

the interfaces to the link providers generates this CENLOG.<br />

DLCMAN (230): Requested Link Provider not registered<br />

Description: DLCMAN received a command for which there is no target IA. The<br />

command is rejected. The data link control manager service module that maintains<br />

the interfaces to the link providers generates this CENLOG.<br />

DLCMAN (231): CLOSE Line pending<br />

Description: DLCMAN forwarded a down line request to the appropriate LPIA. The<br />

data link control manager service module that maintains the interfaces to the link<br />

providers generates this CENLOG.<br />

DLCMAN (232): CLOSE Line complete<br />

Description: DLCMAN received confirmation from an LPIA indicating line down<br />

processing is complete. The data link control manager service module that maintains<br />

the interfaces to the link providers generates this CENLOG.<br />