Event 3 EVENT/ERROR DETECTED AT L3 (NETWORK)<br />

X.25: L4 Call Request Cleared, R11=reason<br />

Description: The layer 3 module (PDNL3) was unable to successfully process a Call<br />

Request primitive received across the Layer 3/4 Platform interface. Instead of sending<br />

a call request packet to the network, PDNL3 returned a Clear Indication primitive to<br />

the layer 4 module.<br />

R11: Clear primitive’s diagnostic code. For a description of the codes, refer to<br />

Appendix A of this manual.<br />

R12–R15: May contain the called DTE address digits<br />

Attributes affected: Supplementary text message. The X.25 PSCS program product<br />

generates this CENLOG. Procedure: PDNL3.<br />

X.25 Link Area Full<br />

Description: The PDNL3 module was unable to save a data message for later<br />

transmission to the network or layer 4 for a particular virtual circuit. No link area<br />

indexes were available. PDNL3 clears the virtual circuit.<br />

Attributes affected: Supplementary text message. The X.25 PSCS program product<br />

generates this CENLOG. Procedure: PDNL3.<br />

X.25 Network Layer Event<br />

Description: The Common Network Management Service (CNMS) X.25 interface<br />

module in PDNSVS received an alarm notification. (CNMS does not need to be in<br />

operating for this CENLOG to be enabled.) The reason code is passed and displayed<br />

by register R12. This event includes the LINE name, and could include the DTE<br />

statement name or address information.<br />

R8: PDNGRP STE index<br />

R9: May contain the logical channel number<br />

R10: May contain a packet’s cause code. See Appendix C of this manual for a<br />

description of the cause code.<br />

R11: May contain a packet’s diagnostic code. See Appendix A of this manual for a<br />

description of the diagnostic code.<br />

R12: CNMS alarm code<br />

Attributes affected: Supplementary text message, Line event, may include CNMS<br />

interface packet. The X.25 PSCS program product generates this CENLOG.<br />

Procedure: PDNSVS.<br />

X.25 - PCALL Trace File Error - No Space<br />

Description: The NMS TRAC SNAP=X25 command was used to enable tracing during<br />

establishment of a virtual circuit. An error occurred while cataloging the trace file<br />

used by the PDNCALL module.<br />

13–64 7436 0728–303