12.07.2015 Views

Configuration Handbook - Kamami.pl

Configuration Handbook - Kamami.pl

Configuration Handbook - Kamami.pl

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Configuring Stratix II & Stratix II GX DevicesFigure 7–10. Multi<strong>pl</strong>e-Device FPP <strong>Configuration</strong> Using an Enhanced <strong>Configuration</strong> Device When Bothdevices Receive the Same DataV CC (1)V CC (1)10 kΩ (3)(3) 10 kΩStratix II DeviceStratix II DeviceEnhanced<strong>Configuration</strong> DeviceDCLKDCLKDCLKGNDMSEL[3..0]DATA[7..0]nSTATUSCONF_DONEGNDMSEL[3..0]DATA[7..0]nSTATUSCONF_DONEDATA[7..0]OE (3)nCS (3)nCONFIGnCONFIGnINIT_CONF (2)(4) N.C.nCEOnCE(4) N.C.nCEOnCEGNDGNDNotes to Figure 7–10:(1) The pull-up resistor should be connected to the same sup<strong>pl</strong>y voltage as the configuration device.(2) The nINIT_CONF pin is available on enhanced configuration devices and has an internal pull-up resistor that isalways active. This means an external pull-up resistor should not be used on the nINIT_CONF-nCONFIG line. ThenINIT_CONF pin does not need to be connected if its functionality is not used. If nINIT_CONF is not used, nCONFIGmust be pulled to V CC either directly or through a resistor.(3) The enhanced configuration devices’ OE and nCS pins have internal programmable pull-up resistors. If internalpull-up resistors are used, external pull-up resistors should not be used on these pins. The internal pull-up resistorsare used by default in the Quartus II software. To turn off the internal pull-up resistors, check the Disable nCS andOE pull-ups on configuration device option when generating programming files.(4) The nCEO pins of both devices are left unconnected when configuring the same configuration data into multi<strong>pl</strong>edevices.You can use a single enhanced configuration chain to configure multi<strong>pl</strong>eStratix II or Stratix II GX devices with other Altera devices that supportFPP configuration, such as Stratix and Stratix GX devices. To ensure thatall devices in the chain com<strong>pl</strong>ete configuration at the same time or that anerror flagged by one device initiates reconfiguration in all devices, all ofthe device CONF_DONE and nSTATUS pins must be tied together.fFor more information on configuring multi<strong>pl</strong>e Altera devices in the sameconfiguration chain, refer to Configuring Mixed Altera device Chains in the<strong>Configuration</strong> <strong>Handbook</strong>.Altera Corporation 7–33May 2007 Stratix II Device <strong>Handbook</strong>, Volume 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!