12.07.2015 Views

Configuration Handbook - Kamami.pl

Configuration Handbook - Kamami.pl

Configuration Handbook - Kamami.pl

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Configuring Cyclone II DevicesIf your system has multi<strong>pl</strong>e Cyclone II devices (in the same density andpackage) with the same configuration data, you can configure them inone configuration cycle by connecting all device’s nCE pins to ground andconnecting all the Cyclone II device’s configuration pins (nCONFIG,nSTATUS, DCLK, DATA0, and CONF_DONE) together. You can also use thenCEO pin as a user I/O pin after configuration. The configuration signalsmay require buffering to ensure signal integrity and prevent clock skewproblems. Make sure the DCLK and DATA lines are buffered for everyfourth device. All devices start and com<strong>pl</strong>ete configuration at the sametime. Figure 13–11 shows multi<strong>pl</strong>e device PS configuration when bothCyclone II devices are receiving the same configuration data.Figure 13–11. Multi<strong>pl</strong>e Device PS <strong>Configuration</strong> When Both FPGAs Receive the Same DataADDRMemoryDATA0V CC (1)V CC (1)V CCV CC10 kΩ 10 kΩCyclone II DeviceCyclone II DeviceCONF_DONEMSEL1MSEL0CONF_DONEMSEL1MSEL0External Host(MAX II Deviceor Microprocessor)GNDnSTATUSnCEDATA0nCONFIGGNDnCEO N.C. (3)GNDnSTATUSnCEDATA0nCONFIGGNDnCEO N.C. (2)DCLKDCLKNotes to Figure 13–11:(1) The pull-up resistor should be connected to a sup<strong>pl</strong>y that provides an acceptable input signal for all devices in thechain. V CC should be high enough to meet the V IH specification of the I/O on the devices and the external host.(2) The nCEO pins of both devices can be left unconnected or used as user I/O pins when configuring the sameconfiguration data into multi<strong>pl</strong>e devices.You can use a single configuration chain to configure Cyclone II deviceswith other Altera devices. Connect all the Cyclone II device’s and allother Altera device’s CONF_DONE and nSTATUS pins together so alldevices in the chain com<strong>pl</strong>ete configuration at the same time or that anerror reported by one device initiates reconfiguration in all devices.fFor more information on configuring multi<strong>pl</strong>e Altera devices in the sameconfiguration chain, see Configuring Mixed Altera FPGA Chains in the<strong>Configuration</strong> <strong>Handbook</strong>.Altera Corporation 13–29February 2007 Cyclone II Device <strong>Handbook</strong>, Volume 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!