Configuring APEX 20KE & APEX 20KC DevicesIf the Auto-Restart <strong>Configuration</strong> After Error option is turned on, the FPGAsrelease their nSTATUS pins after a reset time-out period (maximum of 40µs). After all nSTATUS pins are released and pulled high, themicroprocessor can try to reconfigure the chain without needing to pulsenCONFIG low. If this option is turned off, the microprocessor mustgenerate a low-to-high transition (with a low pulse of at least 8 µs) onnCONFIG to restart the configuration process.In your system, you can have multi<strong>pl</strong>e devices that contain the sameconfiguration data. To support this configuration scheme, all device nCEinputs are tied to GND, while nCEO pins are left floating. All otherconfiguration pins (nCONFIG, nSTATUS, DCLK, DATA0, and CONF_DONE)are connected to every device in the chain. You should pay specialattention to the configuration signals because they can require bufferingto ensure signal integrity and prevent clock skew problems. Specifically,ensure that the DCLK and DATA lines are buffered for every fourth device.Devices must be the same density and package. All devices will start andcom<strong>pl</strong>ete configuration at the same time. Figure 7–11 shows multi-devicePS configuration when both APEX 20KE and APEX 20KC devices arereceiving the same configuration data.Figure 7–11. Multi<strong>pl</strong>e-Device PS <strong>Configuration</strong> Using a Microprocessor When Both FPGAs Receive the SameDataMemoryADDRDATA0VCC (1)10 kΩVCC (1)10 kΩAPEX 20KE orAPEX 20KC DeviceAPEX 20KE orAPEX 20KC DeviceCONF_DONEMSEL1MSEL0CONF_DONEMSEL1MSEL0MicroprocessorGNDnSTATUSnCEDATA0nCONFIGGNDnCEO N.C. (2)GNDnSTATUSnCEDATA0nCONFIGGNDnCEO N.C. (2)DCLKDCLKNotes to Figure 7–11:(1) The pull-up resistor should be connected to a sup<strong>pl</strong>y that provides an acceptable input signal for all devices in thechain.(2) The nCEO pins of both devices are left unconnected when configuring the same configuration data into multi<strong>pl</strong>edevices.Altera Corporation 7–25August 2005 <strong>Configuration</strong> <strong>Handbook</strong>, Volume 1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!