12.07.2015 Views

Configuration Handbook - Kamami.pl

Configuration Handbook - Kamami.pl

Configuration Handbook - Kamami.pl

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Configuring Stratix & Stratix GX DevicesFigure 11–7. Configuring with a Combined PS & <strong>Configuration</strong> Device Scheme10 kΩV CC (1)VCC (1)V CC 10 kΩ V CC (1)10 kΩ (2)(6)10 kΩV CC (1)Stratix or Stratix GX Device(6)MSEL0MSEL1MSEL2nCECONF_DONEnSTATUSDCLKnCEON.C.(2)V CC (1)10 kΩDownload Cable10-Pin Male Header(PS Mode)Pin 1V CCGNDVIO (3)GNDDATA0nCONFIG(4) (4) (4)GND<strong>Configuration</strong>Device(4)(4)DCLKDATAOE (6)nCS (6)nINIT_CONF (5)Notes to Figure 11–7:(1) You should connect the pull-up resistor to the same sup<strong>pl</strong>y voltage as the configuration device.(2) The pull-up resistors on the DATA0 and DCLK pins are only needed if the download cable is the only configurationscheme used on the board. This is to ensure that the DATA0 and DCLK pins are not left floating after configuration.For exam<strong>pl</strong>e, if the design also uses a configuration device, the pull-up resistors on the DATA0 and DCLK pins arenot necessary.(3) Pin 6 of the header is a V IO reference voltage for the MasterBlaster output driver. V IO should match the targetdevice’s V CCIO . This is a no-connect pin for the ByteBlasterMV header.(4) You should not attempt configuration with a download cable while a configuration device is connected to a Stratixor Stratix GX device. Instead, you should either remove the configuration device from its socket when using thedownload cable or <strong>pl</strong>ace a switch on the five common signals between the download cable and the configurationdevice. Remove the download cable when configuring with a configuration device.(5) If nINIT_CONF is not used, nCONFIG must be pulled to V CC either directly or through a resistor.(6) If external pull-ups are used on CONF_DONE and nSTATUS pins, they should always be 10 kΩ resistors. You can usethe internal pull-ups of the configuration device only if the CONF_DONE and nSTATUS signals are pulled-up to 3.3 Vor 2.5 V (not 1.8 V or 1.5 V).fFor more information on how to use the MasterBlaster or ByteBlasterMVcables, see the following documents:■■■■USB-Blaster USB Port Download Cable Data SheetMasterBlaster Serial/USB Communications Cable Data SheetByteBlasterMV Parallel Port Download Cable Data SheetByteBlaster II Parallel Port Download Cable Data SheetAltera Corporation 11–17July 2005 Stratix Device <strong>Handbook</strong>, Volume 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!