12.07.2015 Views

Configuration Handbook - Kamami.pl

Configuration Handbook - Kamami.pl

Configuration Handbook - Kamami.pl

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Passive Serial <strong>Configuration</strong>option is disabled in the SOF when programming the device using theQuartus II programmer and download cable. Therefore, if you turn onthe CLKUSR option, you do not need to provide a clock on CLKUSR whenyou are configuring the device with the Quartus II programmer and adownload cable. Figure 11–26 shows PS configuration for Stratix IIIdevices using a USB Blaster, MasterBlaster, ByteBlaster II, orByteBlasterMV cable.Figure 11–26. PS <strong>Configuration</strong> Using a USB Blaster, MasterBlaster, ByteBlaster II, or ByteBlasterMV CableV CC (1)V CC (1)V CC (1)V CC (1)10 kΩ(2)V CC (1)10 kΩV CCStratix III DeviceCONF_DONEnSTATUSMSEL210 kΩ10 kΩ10 kΩ(2)MSEL1MSEL0GNDGNDnCEDCLKDATA0nCONFIGnCEON.C.Download Cable10-Pin Male Header(PS Mode)Pin 1V CCGNDV IO (3)ShieldGNDNotes to Figure 11–26:(1) You should connect the pull-up resistor to the same sup<strong>pl</strong>y voltage as the USB Blaster, MasterBlaster (V IO pin),ByteBlaster II, or ByteBlasterMV cable.(2) You only need the pull-up resistors on DATA0 and DCLK if the download cable is the only configuration scheme usedon your board. This ensures that DATA0 and DCLK are not left floating after configuration. For exam<strong>pl</strong>e, if you arealso using a configuration device, you do not need the pull-up resistors on DATA0 and DCLK.(3) Pin 6 of the header is a V IO reference voltage for the MasterBlaster output driver. V IO should match the device'sV CCIO . Refer to the MasterBlaster Serial/USB Communications Cable Data Sheet for this value. In the ByteBlasterMVcable, this pin is a no connect. In the USB Blaster and ByteBlaster II cables, this pin is connected to nCE when it isused for active serial programming, otherwise it is a no connect.You can use a download cable to configure multi<strong>pl</strong>e Stratix III devices byconnecting each device's nCEO pin to the subsequent device's nCE pin.The first device's nCE pin is connected to GND while its nCEO pin isconnected to the nCE of the next device in the chain. The last device's nCEinput comes from the previous device, while its nCEO pin is left floating.All other configuration pins (nCONFIG, nSTATUS, DCLK, DATA0, andCONF_DONE) are connected to every device in the chain. Because allCONF_DONE pins are tied together, all devices in the chain initialize andenter user mode at the same time.11–62 Altera CorporationStratix III Device <strong>Handbook</strong>, Volume 1 May 2007

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!