Serial <strong>Configuration</strong> Devices (EPCS1, EPCS4, EPCS16, & EPCS64) FeaturesTable 4–22. Absolute Maximum Ratings Note (1) (Part 2 of 2)Symbol Parameter Condition Min Max UnitT AMB Ambient temperature Under bias −65 135 ° CT J Junction temperature Under bias 135 ° CTable 4–23. Recommended Operating ConditionsSymbol Parameter Conditions Min Max UnitV CC Sup<strong>pl</strong>y voltage (2) 3.0 3.6 VV I Input voltage Respect to GND −0.3 0.3 + V CC VV O Output voltage 0 V CC VT A Operating temperature For commercial use 0 70 ° CFor industrial use −40 85 ° Ct R Input rise time 5 nst F Input fall time 5 nsTable 4–24. DC Operating ConditionsSymbol Parameter Conditions Min Max UnitV IH High-level input voltage 0.7 × V CC V CC + 0.4 VV IL Low-level input voltage −0.5 0.3 × V CC VV OH High-level output voltage I OH = −100 μA (3) V CC −0.2 VV OL Low-level output voltage I OL = 1.6 mA (3) 0.4 VI I Input leakage current V I = V CC or GND −10 10 μAI OZ Tri-state output off-state current V O = V CC or GND −10 10 μATable 4–25. I CC Sup<strong>pl</strong>y CurrentSymbol Parameter Conditions Min Max UnitI CC0 V CC sup<strong>pl</strong>y current (standby) 50 (5) μAI CC1 V CC sup<strong>pl</strong>y current (during activepower mode)5 15 mAAltera Corporation 4–37April 2007 <strong>Configuration</strong> <strong>Handbook</strong>, Volume 2