R&S <strong>FSQ</strong> Instrument Functions<br />

SELECT<br />

TRACE<br />

HOLD CONT (ON OFF)<br />

AVG MODE<br />

ASCII FILE EXPORT<br />

DECIM SEP<br />

COPY TRACE<br />

<strong>Analyzer</strong> Mode<br />

The SELECT TRACE softkey activates the entry for the active trace (1, 2, 3).<br />

Remote command: -- (selected via numeric suffix of: TRACe)<br />

CLEAR/WRITE The CLEAR/WRITE softkey activates the overwrite mode for the collected measured<br />

values, i.e. the trace is overwritten by each sweep.<br />

In the CLEAR/WRITE display mode all the available detectors can be selected. In<br />

the default mode the autopeak detector (setting AUTO) is selected.<br />

Each time the CLEAR/WRITE softkey is actuated, R&S <strong>FSQ</strong> clears the selected<br />

trace memory and starts the measurement anew.<br />

Remote command: DISP:WIND:TRAC:MODE WRIT<br />

MAX HOLD The MAX HOLD softkey activates the max peak detector.<br />

The R&S <strong>FSQ</strong> saves the sweep result in the trace memory only if the new value is<br />

greater than the previous one.<br />

The detector is automatically set to MAX PEAK. The maximum value of a signal can<br />

thus be determined over several sweeps.<br />

This is especially useful with modulated or impulsive signals. The signal spectrum is<br />

filled up upon each sweep until all signal components are detected in a kind of envelope.<br />

Pressing the MAX HOLD softkey again clears the trace memory and restarts the<br />

max hold mode.<br />

Remote command: DISP:WIND:TRAC:MODE MAXH<br />

AVERAGE The AVERAGE softkey activates the trace averaging function. The average is<br />

formed over several sweeps. Averaging can be performed with any of the detectors<br />

available. If the detector is automatically selected by R&S <strong>FSQ</strong>, the sample detector<br />

is used.<br />

Depending on the setting of AVG MODE, the logarithmic level values or the measured<br />

power/voltage values are averaged.<br />

Averaging is restarted every time the AVERAGE softkey is pressed. The trace memory<br />

is always cleared.<br />

Remote command: DISP:WIND:TRAC:MODE AVER<br />

Operating Manual 1313.9681.12 - 01 4.41