R&S <strong>FSQ</strong> Remote Control – Description of Commands<br />

"CALC2:DELT:TRAC 3"<br />

'Assigns delta marker 1 to trace 3 in screen B.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

CALCulate:DELTamarker:X 0 to MAX (frequency | sweep time)<br />

CALCulate Subsystem<br />

This command positions the selected delta marker in the indicated measurement window to the<br />

indicated frequency (span > 0), time (span = 0) or level (APD measurement = ON or CCDF<br />

measurement = ON). The input is in absolute values or relative to marker 1 depending on the<br />

command CALCulate:DELTamarker:MODE. If the reference fixed measurement (CALCulate:<br />

DELTamarker:FUNCtion:FIXed:STATe ON) is active, relative values refer to the reference<br />

position are entered. The query always returns absolute values.<br />

Example: "CALC:DELT:MOD REL"<br />

'Switches the input for all delta markers to relative to marker 1.<br />

"CALC:DELT2:X 10.7MHz"<br />

'Positions delta marker 2 in screen A 10.7 MHz to the right of marker 1.<br />

"CALC2:DELT:X?"<br />

'Outputs the absolute frequency/time of delta marker 1 in screen B<br />

"CALC2:DELT:X:REL?"<br />

'Outputs the relative frequency/time/level of delta marker 1 in screen B<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

CALCulate:DELTamarker:X:RELative?<br />

This command queries the frequency (span > 0) or time (span = 0) of the selected delta marker relative<br />

to marker 1 or to the reference position (for CALCulate:DELTamarker:FUNCtion:FIXed:STATe<br />

ON). The command activates the corresponding delta marker, if necessary.<br />

Example: "CALC:DELT3:X:REL?"<br />

'Outputs the frequency of delta marker 3 in screen B relative to marker 1 or relative<br />

to the reference position.<br />

Characteristics: *RST value: -<br />

SCPI: device-specific<br />

Mode: A<br />

CALCulate:DELTamarker:Y?<br />

This command queries the measured value of the selected delta marker in the indicated measurement<br />

window. The corresponding delta marker will be activated, if necessary. The output is always a relative<br />

value referred to marker 1 or to the reference position (reference fixed active).<br />

To obtain a valid query result, a complete sweep with synchronization to the sweep end must be<br />

performed between the activation of the delta marker and the query of the y value. This is only possible<br />

in single-sweep mode.<br />

Depending on the unit defined with CALC:UNIT or on the activated measuring functions, the query<br />

result is output in the units below:<br />

6.20 Operating Manual 1313.9681.12 - 01