R&S <strong>FSQ</strong> Instrument Functions<br />

Basic Settings<br />

For 8566A/B, 8568A/B and 8594E, command sets A and B are available. Command<br />

sets A and B differ in the rules regarding the command structure from the<br />

command structure of “SCPI”. Therefore, correct recognition of SCPI commands is<br />

not ensured in these operating modes.<br />

Selecting a language different from "SCPI" will set the GPIB address to 18 if it was<br />

20 before.<br />

Start / stop frequency, reference level and # of sweep points will be adapted to the<br />

selected instrument model.<br />

8568A_DC and 8568B_DC are using DC input coupling as default if it is supported<br />

by the instrument.<br />

The HP model 8591E is compatible to HP model 8594E, the HP models 71100C,<br />

71200C, and 71209A are compatible to HP models 8566A/B.<br />

On switching between remote-control languages, the following settings or changes<br />

will be made:<br />

SCPI:<br />

➢ The instrument will perform a PRESET.<br />

8566A/B, 8568A/B, 8594E:<br />

➢ The instrument will perform a PRESET.<br />

➢ The following instrument settings will then be changed:<br />

Model # of Trace<br />

Points<br />

Start Freq. Stop Freq. Ref Level Input<br />

Coupling<br />

8566A/B 1001 2 GHz 22 GHz 0 dBm DC<br />

8568A/B 1001 0 Hz 1.5 GHz 0 dBm AC<br />

8560E 601 0 Hz 2.9 GHz 0 dBm AC<br />

8561E 601 0 Hz 6.5 GHz 0 dBm AC<br />

8562E 601 0 Hz 13.2 GHz 0 dBm AC<br />

8563E 601 0 Hz 26.5 GHz 0 dBm AC<br />

8564E 601 0 Hz 40 GHz 0 dBm AC<br />

8565E 601 0 Hz 50 GHz 0 dBm AC<br />

8594E 401 0 Hz 3 GHz 0 dBm AC<br />

Notes regarding switch over to 8566A/B and 8568A/B on R&S FSUP<br />

• The stop frequency indicated in the table may be limited to the corresponding<br />

frequency of the R&S <strong>FSQ</strong>, if required.<br />

Remote command: SYST:LANG "SCPI" | "8560E" | "8561E" |<br />

"8562E" | "8563E" | "8564E" | "8565E" |<br />

"8566A" | "8566B" | "8568A" |<br />

"8568A_DC" | "8568B" | "8568B_DC" |<br />

"8591E" | "8594E" | "71100C" | "71200C" |<br />

"71209A"<br />