R&S <strong>FSQ</strong> Instrument Functions<br />

Basic Settings<br />

OPTIONS Opens a table that provides information about installed firmware options. Also opens<br />

a submenu to manage firmware options.<br />

INSTALL<br />

OPTION<br />

REMOVE<br />

OPTION<br />

INSTALL OPTION<br />

REMOVE OPTION<br />

EXPERT MODE<br />

REBOOT<br />

PAGE UP /<br />

PAGE DOWN<br />

INSTALL (FW EXT)<br />

The INSTALL OPTION softkey opens the data entry for the license keycode of a<br />

firmware option.<br />

On entry of a valid license key the message OPTION KEY OK is displayed in the<br />

status line and the firmware option appears in table FIRMWARE OPTIONS.<br />

If the license key is valid and accepted, the R&S <strong>FSQ</strong> activates that option by<br />

default. If the R&S <strong>FSQ</strong> has memory issues, you have to deactivate other applications<br />

before you can use the option (see OPTIONS softkey).<br />

On entry of an invalid license key the message OPTION KEY INVALID is displayed<br />

in the status line.<br />

Remote command: --<br />

The REMOVE OPTION softkey removes all firmware options from the instruments.<br />

Execution of this function must be confirmed in a message box in order to avoid<br />

removal of the firmware options by mistake.<br />

Remote command: --<br />

EXPERT MODE The EXPERT MODE softkey switches off the option key memory check.<br />

This function is useful if all the required applications do not fit into the available system<br />

memory, but the worst case settings (concerning memory usage) of the applications<br />

is not required for a certain test case.<br />

Example: An application may only need the maxmimum memory if a certain function<br />

(e.g. FFT calculation) is active. If this function is not used, it is possible to enable an<br />

additional application.<br />

The analyzer may crash do to "low memory" conditions if the expert mode is<br />

switched on.<br />

Remote command: ---<br />

REBOOT The REBOOT softkey performs the shutdown and reboot of the operating system<br />

and the analyzer firmware. The reboot will free allocated resources.<br />

Remote command: ---<br />

4.194 Operating Manual 1313.9681.12 - 01